Air/Oxygen Fed, water cooled ozone generator. 3-10 pound per day using air as a feed gas.
Water Cooled Ozone Options to Customize the Units:
40 grams/per hour @ 2%, 25 LPM air at 20 PSI. water source required - 1.0 GPM @70 F. 230/1/60, 10 Amps 80 grams/per hour @5%, 15 LPM O2 at 20 PSI. water source required - 1.0 GPM @70 F. 230/1/60, 10 Amps 80 grams/per hour @ 2%, 50 LPM air at 20 PSI. water source required - 3.0 GPM @70 F. 230/1/60, 15 Amps 160 grams/per hour @5%, 30 LPM O2 at 20 PSI. water source required - 3.0 GPM @70 F. 230/1/60, 15 Amps 120 grams/per hour @ 2%, 100 LPM air at 20 PSI. water source required - 4.0 GPM @70 F. 230/1/60, 20 Amps. 240 grams/per hour @5% 40 LPM o2 at 20 PSI. water source required -4.0 GPM @70 F. 230/1/60, 20 Amps.
Feed gas requirements: • Maximum dewpoint: -70 degree F. • Minimum feed gas supply pressure: 40 PSI.
Cooling water requirements: • Filtered prior to ozone generator. • Maximum conductivity of • Maximum hardness of • Treated closed loop cooling highly recommended.
Standard: • 50 or 60 Hz capable. • Two customer interlocks. • Variable output. • Amp meter. • Gas pressure switch. • Gas flow meter. • Cooling water flow meter. • Cell cooling water temperature switch. • Cabinet filter. • Backflow prevention device.
Optional: • Integrated ORP transmitter. • Dewpoint analyzer. • Air dryer. • Air dryer pre filters. • Oxygen concentrator